What do the RR and RS LEDs of the RGS200-12P switch indicate?

Question

The RGS200-12P outdoor switch has two LEDs on the left of the GBIC slots.

What do RR and RS stand for?

Answer

The RR and RS LED indicators are for the RGS200-12P's fast failover ring feature.

 

The RR (Redundant Role) LED is ON if:

   - a "Redundant Master" is enabled in the system.

The RR (Redundant Role) LED is OFF if:

   - there is no "Redundant Master" enabled in the system.

 

The RS (Redundant Status) LED is ON if:

   - any of the local ring port's status is down.

   - the "Redundant Master" is no longer reachable.

The RS (Redundant Status) LED is OFF if:

   - a "Redundant Master" is enabled in the system.